Bomb Blast Tests

Ultra Film Strength Blast Tests

These movies show the results of actual  controlled blast tests.

Identical "rooms" were set up around the blast site; equal distances away.

No Security Film
Click here to view test movie
Damage Description Glazing failed and entered the structure at high velocity
Glass Fragment Location 95% of glass entered structure with 5% outside to about 12 ft in front of structure, 98 impacts on witness panel, 82 below 2ft height 16 above 2ft height
Fragment Hazard to Occupants Significant hazard to persons within 10-15ft behind window
Condition 5
Ultra 400 Security Film
Click here to view test movie
Damage Description Glazing failed and window left frame, landed 18 inches from front of structure:
Glass Fragment Location Small dicing a few fragments inside, no impacts on witness panels, frags to 20ft in front of structure, about 95-97% glass retained on film
Fragment Hazard to Occupants Minor hazard to occupants within 10ft behind window
Condition 3-SHR
Ultra 400 Security Film and batten fixed to frame
Click here to view test movie
Damage Description Glazing failed and film was retained intact in frame with no openings, aluminium frame bowed on all sides.
Glass Fragment Location No fragments inside structure, frags to 47ft in front of structure, about 30% glass retained on film.
Fragment Hazard to Occupants No hazard to occupants
Condition 2